Features
 
    The sensor and the instrument are fully equipped; the relay in the instrument allows 16A current through its contact, it can control the load within 2KW directly. The instrument can realize the function of temperature control independently without other components.
  It is easy to install, use and maintain.
  Temperature coefficient below 50ppm, the meter can work stably within the allowable ambient temperature.
  The special technology makes the meter work stably and response quickly.
  It can control two sets of devices independently at up and down limits.
  It is powered off automatically when the sensor is at the open circuit state, this makes the meter work securely and stably.
  It can do Long-distance measuring and controlling.
  The proprietary design and technology.

 

 

 
 
Technical Specifications¡¡
¡¡Measuring Rang -200 to 50¡æ£¬-50 to 200¡æ£¬0 to 300¡æ£¬0 to 600¡æ
¡¡Accuracy ¡À0.5%FS¡À1d
¡¡Response Time 2 to 10 seconds
¡¡Set Point Error ¡Ü0.5¡æ(-200 to 200¡æ)£»¡Ü2¡æ(0 to 600¡æ)
¡¡Resolution 0.1¡æ(-200 to 200¡æ)£»1¡æ(0 to 600¡æ)
¡¡Relay Contact Capacity AC¡¢220V¡¢16A£»maximum control load:2KW(AC 220V)
¡¡Dimensions 160¡Á80¡Á80mm(L¡ÁH¡ÁD); mounting hole:152¡Á76mm
¡¡Power Consumption 4W

 

 

Matching Sensors£º
The sensitive components of temperature sensor are silicon semiconductor and platinum resistance. Protective materials are stainless steel, copper, nickel and glass etc. Please use the special shielding material to protect the sensor when you want to measure the temperature of strong acid and alkaline matters. The familiar forms are as follows:

¡¡¡¡JM10£¬Rod with handle sensor(1). For inserting into the gas, the liquid and the solid crevice, such as steam, various fluid (including melting tin, aluminum, zinc, and etc.), soft and granulated solid, like grain, threaded tobacco, paper, soil, unsolidified concrete, and asphalt etc.

¡¡¡¡JM20£¬Short columnar sensor(2), For throwing or planting into the deep place of the gas, the liquid and the solid, also for installing in the measured gap or pasting on the wall of containers.
¡¡

¡¡¡¡JM30£¬Flake sensor(3), For measuring the surface temperature of specific positions, its shape and thickness could be selected at will, the sensor also can be pasted, clamped, and fixed with bolt or other methods to install.
¡¡

¡¡¡¡JM40£¬Rod with fixing bolt sensor. It has telescoping(4)and stationary(5)types. For installing on various kinds of pipelines and containers, equipped with connecting box, the fixing and dismantling of sensor are convenient.
¡¡¡¡JM60£¬The surface sensor. Suitable for plane or curved surfaces' temperature measurement.

 

 

 
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡Operating conditions
Ambient temperature£º-200 to 50¡æ
Relative humidity£º¡Ü85%RH
Power supply£ºAC¡¢220V¡¢50/60HZ

 

 

  JM262 temperature controller can be used for temperature monitoring, single and double limits temperature autocontrol, and temperature switch etc.
  JM262 is simple switch control mode, when it is used for thermostatic control, the temperature will undulate; thermostatic effect not only depends on the performance of temperature controller, but also has something to do with the heating or refrigeration devices and thermal property of the controlled system.
  JM262 Generally speaking, if you want to get a constant temperature or temperature area, the heat capacity of heating or refrigeration device is smaller, the one that of corresponded heating and cooling system is bigger£»the difference between operation temperature and the control temperature is smaller, the undulation of temperature is smaller. For example, heating water with electric heater which is controlled by JM262 under the situation of mixing round, you will get the thermostatic effect of undulation ¡Ü 0.2¡æ.
  JM262 If what you want to control is a stable temperature range, then you can realize it through high-low limit control. In common refrigeration control, because of refrigerator can not be started or stopped frequently, also the low temperature ambient is mostly a temperature area, not requested strictly to be a constant temperature, such as: cold storage, cold wind storage, various refrigerators, water organism cultivations boxes, and cryogenic artificial ambient etc, so JM262 can realize this kind of temperature control well.
  JM262 is convenient to use. First to connect the lead of sensor or insert the plug of sensor in the backboard according to the position that marked, and then fix the sensor, keep the sensitive part of sensor has good thermocontact with the object that will be controlled, and reduce the influence of ambient temperature as far as possible. After that, according to the demands to string the switch on or switch out contact into the power circuit of controlled equipment (do not exceed the allowed power), connect the power line of controller, check the connection of each part without any error, then press the switch of power supply, you will see the temperature manifestation. Afterwards, move the selection switch to the set point position, here the digital manifestation is set point value, adjust the set point potentiometer to make the temperature equal to the alarm temperature or the temperature that will be controlled, and then move the selection switch again to the position that controlled, the instrument will display the measured temperature and enter in a state of autocontrol.
  JM262 is panel meter. Please push over instrument after making a hole on the panel according to the size that marked while installing.

 

  Do not exceed the temperature area.
  Do not exceed the permission control load.£¨AC 220V 2KW£©
  Please use the shielding line which must be put to earth effectively to connect the sensor and instrument while doing long-distance measurement.
  Keep away from the strong electromagnetic field as far as possible while installing instrument.
  The calibration of instrument must use standard thermometer and proprietary equipments. A simple examination method is to fill a big vacuum flask with flake ice, add water to 2/3 position, wait 10 minutes after mixing round, then insert the sensor carefully£¬Its figure should be within the area of 0¡æ¡À admission error after the thermometer displays stably; And then insert the sensor into boiling water, here its figure should be within the area of 100¡æ¡À admission error under the environment of one atmospheric pressure.

 

Services
 

¡¡We provide repair freely for one year. Other cities¡¯ customers can rely on quality card (or photocopy) mail to repair. After receive the meter we will repair it in five days and then send back.

¡¡The non-warranty repair of other cities¡¯ customers also could mail. We will repair the meter in five days after receive it, then tell you the expense of repair (only receive cost price), and will return it in two days after receive your money. The part of repair also has a three-month warranty.

¡¡You can mail order, please fill in and carry out the card that attached in detail.

¡¡Welcome to write to us for asking and obtaining data.

 